Difference between revisions of "IETF 97 Hackathon ietf-alarms model implementation for yuma123 report"
From Yuma123 Wiki
Jump to navigationJump to searchLine 6: | Line 6: | ||
==Project goals== |
==Project goals== |
||
===General/Reusable standalone module and C library code=== |
===General/Reusable standalone module and C library code=== |
||
− | * ietf-alarms.c - implementation of ietf-alarms.yang. Handles list management container registrations etc. |
+ | * [https://sourceforge.net/p/yuma123/git/ci/master/tree/example-modules/ietf-alarms/ietf-alarms.c ietf-alarms.c] - implementation of ietf-alarms.yang. Handles list management container registrations etc. |
− | * alarmctrl. |
+ | * [https://sourceforge.net/p/yuma123/git/ci/master/tree/example-modules/ietf-alarms/alarmctrl.c alarmctrl.c],h - device side alarm generation helper library (handles the registration of alarm entries). Simple 1 API function: |
===Usage example code=== |
===Usage example code=== |
||
− | * interfaces-alarms.yang (NEW) - model defining link-alarm |
+ | * [https://sourceforge.net/p/yuma123/git/ci/master/tree/example-modules/ietf-interfaces/interfaces-alarms.yang interfaces-alarms.yang] (NEW) - model defining link-alarm |
− | * interfaces-alarms.c (NEW) - implementation of alarms-interfaces.yang based on interception of link-up and link-down |
+ | * [https://sourceforge.net/p/yuma123/git/ci/master/tree/example-modules/ietf-interfaces/interfaces-alarms.c interfaces-alarms.c] (NEW) - implementation of alarms-interfaces.yang based on interception of link-up and link-down |
− | * interfaces-notifications.yang (NEW) - define link-up and link-down |
+ | * [https://sourceforge.net/p/yuma123/git/ci/master/tree/example-modules/ietf-interfaces/interfaces-notifications.yang interfaces-notifications.yang] (NEW) - define link-up and link-down |
− | * ietf-interfaces.c (MODIFIED) - implement support for link-up and link-down when the interfaces-notifications.yang is loaded |
+ | * [https://sourceforge.net/p/yuma123/git/ci/master/tree/example-modules/ietf-interfaces/ietf-interfaces.c ietf-interfaces.c] (MODIFIED) - implement support for link-up and link-down when the interfaces-notifications.yang is loaded |
==Usage== |
==Usage== |
Revision as of 07:39, 13 November 2016
Contents
Description
ietf-alarms.yang is new standards track model proposal defined in draft-vallin-netmod-alarm-module-01. Lets implement the example the description text of the module has e.g. "...('link-alarm', 'GigabitEthernet0/25'),..."
The implementation is available at sourceforge and github yuma123 repositories.
Project goals
General/Reusable standalone module and C library code
- ietf-alarms.c - implementation of ietf-alarms.yang. Handles list management container registrations etc.
- alarmctrl.c,h - device side alarm generation helper library (handles the registration of alarm entries). Simple 1 API function:
Usage example code
- interfaces-alarms.yang (NEW) - model defining link-alarm
- interfaces-alarms.c (NEW) - implementation of alarms-interfaces.yang based on interception of link-up and link-down
- interfaces-notifications.yang (NEW) - define link-up and link-down
- ietf-interfaces.c (MODIFIED) - implement support for link-up and link-down when the interfaces-notifications.yang is loaded
Usage
Starting the netconf server
/usr/sbin/netconfd --module=ietf-interfaces --module=interfaces-notifications --module=ietf-alarms@2016-10-27 --module=alarms-interfaces --superuser=vladimir
Device side: Simple 1 C function API
int alarmctrl_event(char* resource_str, char* alarm_type_id_str, char* alarm_type_qualifier_str, char* severity_str, char* alarm_text_str, int enable);
Example:
alarmctrl_event("/interfaces/interface[name=\'eth0\']", "link-alarm"/*alarm_type_id_str*/, ""/*alarm_type_qualifier_str*/, "major", "Probably someone disconnected something?!", down?1:0);
User side: yangcli
yangcli vladimir@localhost> xget /alarms rpc-reply { data { alarms { alarm-list { number-of-alarms 2 alarm /interfaces/interface[name='eth0'] alarms-if:link-alarm { resource /interfaces/interface[name='eth0'] alarm-type-id alarms-if:link-alarm alarm-type-qualifier time-created 2016-11-13T05:04:11Z is-cleared false last-changed 2016-11-13T05:16:26Z perceived-severity major } alarm /interfaces/interface[name='eth1'] alarms-if:link-alarm { resource /interfaces/interface[name='eth1'] alarm-type-id alarms-if:link-alarm alarm-type-qualifier time-created 2016-11-13T05:04:11Z is-cleared false last-changed 2016-11-13T05:16:26Z perceived-severity major } } } } }